Contact

Management

Prof Dr Thomas Müller

+49 (0) 441 798-3874

W3 3-338

Scientific management

+49 (0) 441 798-3657

W3 3-353

Research assistants


+49 (0) 441 798-3733

+49 (0) 441 798-3733

+49 (0) 441 798-3733

W3 0-184

BRUKER Avance III 500

in operation since 2009

Two sample heads are available for this NMR spectrometer. The BBI sample head is permanently installed.

Sample head BBI: PA BBI 500S2 H-BB-D-05 Z
With Z-gradient

Inverse sample head: ¹H coil inside - X coil outside - Hetero cores are not as sensitive,
but are favourable for ¹H and ¹H detected 2D spectra, therefore
¹H_X-HMQC and -HMBC are more sensitive than on the BBO sample head.

BBO sample head: PA BBO 500S2 BBF-H-D-05 Z
With Z-gradient

Unfortunately, the 2D experiments no longer work with this sample head. Due to its age, it cannot be repaired.

Sample head: ¹H coil outside - XF coil inside → Hetero nuclei are more sensitive than on the BBI sample head.
With ¹H/¹⁹F switchbox

Temperature experiments are possible for both sample heads from -150°C to +150°C. Care must be taken to select a suitable solvent.

For temperature measurements and experiments that are not measured in the automatic system, please make an appointment.

Experiments:
Further experiments on request

¹H:¹H
¹H_paraWide measuring range for paramagnetic cores; small D1
¹H D1-120s→ d1 (relaxation time) = 120s
¹H¹H COSYH-H correlation within a spin system
¹H¹H TOCSYH-H correlation total
¹H¹H NOESYH-H correlation due to spatial proximity
NOE diff.Differential measurement → no automatic
ProhomodecHomodecoupling → no automatic
1H jres Display of couplings in the second dimension → no automatic
¹H{¹⁹F} BBO sample head only
¹H{³¹P}
¹H{X}Decoupling from other heteronuclei is possible
PSYCHE¹H{¹H}
DOSYDiffusion → no automatic
EXSYChemical exchange → no automatic
Water suppression→ no automatic
Solvent suppression→ no automatic / for non-deuterated solvents / measurement without lock / with "no-D" shim
²HDeuteriumMeasurement on the lock channel
⁷Li:⁷Li{¹H}
¹¹B:¹¹Bwith and without background suppression
¹¹B{¹H} with and without background suppression
¹H¹¹B HMQC
¹H¹¹B HMBC
¹¹B¹¹B COSY
¹¹B¹¹B COSY{¹H}
¹³C:¹³C
¹³C{¹H}
¹³C{¹H} dept135CH₃/CH-positive - CH₂-negative
¹³C{¹H} dept90CH-positive
¹³C{¹H} jmod =aptCH₃/CH-positive - CH₂/C-negative
¹H¹³C HMQCnot phase sensitive
¹H¹³C HSQCphase sensitive (combination of HMQC and dept135)
¹H¹³C HMBC
¹H¹³C HMBC-et1J suppression → no automatic
¹³C{¹H} inept-rdPolarisation transfer
¹³C{¹H} zgig30

inverse gated - integrable → weekend measurement

T1 times must be known

¹³C InadequateNo automatic → Weekend measurement
EXSY ¹³CChemical exchange → no automatic
¹³C jresDisplay of couplings in the second dimension → no automatic
¹⁴N¹⁴N{¹H}
¹⁵N:¹H¹⁵N HMQCCoupling constant + measuring range must be specified
¹H¹⁵N HMBCCoupling constant + measuring range must be specified
¹⁵N{¹H} inept-rdPolarisation transfer → Coupling constant + measuring range must be specified
¹⁵N inept-pndPolarisation transfer → Coupling constant + measuring range must be specified
¹⁵N{¹H} dept135only possible if N is present as ¹⁵N isotope
¹⁵N{¹H} zgigonly possible if N is present as ¹⁵N isotope
¹⁹F:Only possible on the BBO sample head
¹⁹F
¹⁹F{¹H} 300ppmWidth of the measuring range = 300 ppm
¹⁹F{¹H} 150ppmWidth of the measuring range = 150 ppm / centre of the measuring range must be specified
²⁷Al:²⁷Alwith and without background suppression
²⁷Al{¹H} with and without background suppression
¹H²⁷Al HMBC
²⁹Si:²⁹SiWeekend measurement - switch to inept-pnd if possible
²⁹Si{¹H} gatedinverse gated → 3h measurement time - switch to inept-rd if possible
²⁹Si{¹H}-inept-rdPolarisation transfer
²⁹Si-inept-pndPolarisation transfer
¹H²⁹Si HMQC
¹H²⁹Si HMBC
²⁹Si InadequateNo automatic → Weekend measurement
³¹P:³¹P
³¹P{¹H}
³¹P{¹H} gatedinverse gated - integrable → T1 times must be known
¹H³¹P HMQC
¹H³¹P HMBC
³⁵Cl:³⁵Cl{¹H}
⁴⁷Ti:⁴⁷Ti{¹H}aring - antiringing sequence
⁷¹Ga:⁷¹Ga{¹H}
⁷⁵As:⁷⁵As{¹H}
⁷⁷Se:⁷⁷Se
⁷⁷Se{¹H}
¹H⁷⁷Se HMQC
¹H⁷⁷Se HMBC
¹¹⁹Sn:¹¹⁹Sn{¹H} gatedinverse gated
¹H¹¹⁹Sn HMQC
¹H¹¹⁹Sn HMBC
¹¹⁹Sn{¹H} inept-rdPolarisation transfer
¹¹⁹Sn inept-pndPolarisation transfer
¹²⁵Te:¹²⁵Te{¹H} gatedinverse gated
¹H¹²⁵Te HMBC
¹²⁵Te{¹H} inept-rdPolarisation transfer
¹²⁵Te inept-pndPolarisation transfer
¹⁹⁵Pt¹⁹⁵Pt{¹H}
²⁰⁷Pb:²⁰⁷Pb{¹H}

 


 

 

(Changed: 10 Mar 2026)  Kurz-URL:Shortlink: https://uol.de/p84081en